Fig. 3
From: Cell-nanoparticle stickiness and dose delivery in a multi-model in silico platform: DosiGUI

Predictions of adsorbed mass fractions over time. Mass fractions adsorbed by HepG2 cells expressed as a percentage of the total amount of ENP mass in the suspension, obtained running the DG model within DosiGUI and assuming a nominally administered dose of 78.1 µg/cm2. Comparison between the case of a maximally sticky bottom (blue line) and the optimal stickiness identified using the pipeline (orange line) for: (A) TiO2 (NM-105), (B) CeO2 (NM-212) and (C) BaSO4 (NM-220)